Single-stage RO+EDI system

Based on demands of raw water quality conditions and terminal water, single-stage RO +EDI can be used as terminal processing of PW generation system. Quality of water  produced by single-stage RO + EDI is stable, only slightly affected by fluctuation of raw water quality. The water quality conforms to requirements of Chinese pharmacopoeia, European pharmacopoeia and United States pharmacopoeia.

Design of Ideal single-stage RO+EDI system process is reasonable, and chemical, hot water disinfection can be chosen.

Design of internal circulation allows system in low flow running state under the condition of no water demands, avoids risk of growing microorganism during downtime and provides short restart response time. 

The whole system is divided into separate modules, covering small area and with short construction time. 

Design of system assembling adopts professional software, which can automatically generate bill of materials and isometric drawings. Equipment layout and piping structure is reasonable and convenient for operation and maintenance.

The system is fully automatic operation. Variety of operating mode is set to meet different production requirements.